Back to Case Studies

Optimising Cathodic Protection of Main Pipelines

Linear Programming between Under- and Over-Protection

ResearchEnergy, Utilities & EnvironmentSep 2020 – Apr 2022
122.9 km
Real pipeline section optimised
+5–10 yrs
Estimated longer pipeline life
~20–30%
Estimated better corrosion protection
IEEE SIST
Published at the IEEE conference

My Role

Role
Co-author, optimisation model
Academic research
Team
Six co-authors across three universities
Stage reached
Published research
Key decisions
  • Linear programming to minimise total protective current
  • Second iteration strips remaining potential safety margins
  • Re-plan station currents on failure or season

Approach at a Glance

Details
  1. 1Formulating the Problem
  2. 2Multi-Criteria Objective
  3. 3Linear Programming
  4. 4Re-Planning on Failure
  5. 5Seasonal Adaptation

Executive Summary

Main oil and gas pipelines are protected against corrosion electrochemically: cathodic protection stations along the line push a protective current into the pipe so its potential stays in a safe range. In practice that range is hard to hold:

  • Under-protection: too little current leaves corroding zones.
  • Over-protection: too much damages the insulation and causes hydrogen embrittlement of the steel.

Operators usually keep a generous safety margin, which means wasted current and over-protected sections.

This research was part of a government-funded project in Kazakhstan to build an adaptive monitoring and control system for pipeline corrosion protection. My part was the optimisation model, which computes the operating modes of all cathodic stations on a section. It keeps the protective potential within the limits set by the system's intelligent model and minimises the total protective current using linear programming. It also re-plans when a station fails or when weather and soil conditions change.

The approach was modelled on a 122.9 km section of the Akshabulak–Kyzylorda pipeline. According to the project's estimates, keeping protection between the two danger zones extends a pipeline's technical lifetime by at least 5–10 years and increases real protection by about 20–30%. The work was published at the IEEE Smart Information Systems and Technologies conference.


Research Context

The project, funded by the Ministry of Education and Science of the Republic of Kazakhstan (grant AP09261098), developed an information and analytical system for monitoring and controlling electrochemical protection of main pipelines. It brought together:

  • remote measuring points along the pipeline over GSM/GPRS or LoRaWAN;
  • telemechanics on the cathodic stations for remote control;
  • a cloud platform with web and mobile interfaces;
  • an intelligent rule model that sets the required protective-potential limits from conditions such as product temperature, soil resistivity, salts, stray currents and microbiological corrosion.

The optimisation sits on top of that. Given those limits and the current state of the line, the question is what each station should do.


Technical Approach

  1. Formulating the Problem – A pipeline section is modelled with the positions of its cathodic stations and insulating flanges, the current limits of each station, and the permissible bounds of the protective potential along every kilometre, provided by the intelligent model.

  2. Multi-Criteria Objective – The optimisation balances two goals:

    • uniform protective potential along the pipeline, with no under- or over-protected stretches;
    • minimum total protective current across all stations on the section.
  3. Linear Programming – The station currents are found with linear programming: minimise the sum of protective currents, subject to the potential staying within its bounds at every point. A second iteration removes remaining safety margins on the protective potential, cutting over-protection further.

  4. Re-Planning on Failure – When a station goes offline, for example from a power failure, the model computes a new optimal plan for the remaining stations to cover the gap. This was demonstrated on a 130 km stretch.

  5. Seasonal Adaptation – Rain and drought change soil resistivity, and with it how the protective current spreads along the pipe. The model produces adjusted plans for wet and dry seasons from the monitoring data.


Outcome

The optimisation keeps cathodic protection of a pipeline section within the safe range with the least total current, and re-plans automatically when a station fails or the season changes. Modelled on 122.9 km of the Akshabulak–Kyzylorda pipeline, the system is estimated to extend pipeline lifetime by at least 5–10 years and increase real protection by about 20–30%.

Technologies

OptimisationLinear ProgrammingDecision SupportRule-Based SystemsIoT Monitoring

Planning something similar?